Home > Lamps > LED Lamps > Fluorescent Tube Retrofits |
FILE 36/100 |
|
|||
|
File information | |
Filename: | Philips_2ft_LED.JPG |
Album name: | Paul / Fluorescent Tube Retrofits |
Manufacturer: | Philips |
Power Consumption: | 8w |
Overall Length: | 600mm 2ft |
Cap Type: | G13 medium bi-pin |
Cap Finish: | Plastic |
Light Colour Temp: | 4000K |
Lumen Output: | 800lm |
Circuit Type: | Internal driver fed via existing magentic ballast and link-out starter. Or direct mains via bypass. |
Comments: | Going cheap in Homebase so grabbed one to check it out. At 800 lumens it's almost half that of an 18w triphosphor 840 tube! Comes with a linkout starter for use in swicthstart fittings. A warning label is provided for bypassing HF ballasts. |
Country Of Origin: | China |
Filesize: | 348 KiB |
Date added: | Sep 26, 2018 |
Dimensions: | 1600 x 1131 pixels |
Displayed: | 60 times |
URL: | https://allthingslighting.co.uk/atl/displayimage.php?pid=23492 |
Favourites: | Add to Favourites |
Comment 1 to 2 of 2 Page: 1 |
|
|||
They're a bit confusing these, I tried some two foots in the mods at work in one of the offices, and they ran like a bag of crap on series twin circuits???
|
|
|||
Yes that problem isn't mentioned in the instructions I'm sure! Series twin circuits would need rewiring as direct to mains I guess. All too much of a faff for me! And then there's the danger of it being replaced with another fluorescent which will get blown to bits. Every install I've seen that's been retrofitted with LED tubes are always dull and dingy!
|
Comment 1 to 2 of 2 Page: 1 |